• Skip to primary navigation
  • Skip to main content
  • Skip to footer

Email: sales@eaiwater.com

Call: (951) 272-8200

EAI Water

EAI Water

Advancing Industrial Water Treatment Equipment and Services

  • Total Water Management
  • Services
    • Cooling Tower Water Treatment
      • Legionella Control in Cooling Systems
      • Facility Operator Support
      • Water Efficiency
    • Boiler Water Treatment
    • Closed Loop Water Treatment
  • Equipment
    • Pretreatment
      • Industrial Water Softeners
      • Ion Exchange Resins for Makeup Water
    • On-site Chlorine Generation
      • Chlorine Dioxide Generators
      • Electrochemical Chlorine Generator
    • Industrial Reverse Osmosis
    • Industrial Ultrafiltration Systems
  • Industries We Serve
  • Resources
    • Case Studies
    • Blog
    • Partners
    • Operator Resources
  • About Us
    • Our Philosophy
    • Our Team
    • Our Training & Safety
    • EAI News
  • Contact Us

What Is Glycol Used For in Industrial Cooling Systems?

What Is Glycol Used For in Industrial Cooling Systems?

What Exactly Is Glycol – and Why Is It Used?

Glycol is an organic compound from the alcohol family, characterized by two hydroxyl groups. In industrial settings, the two most common types are:

  • Pure Ethylene glycol  – A highly efficient heat transfer fluid used in HVAC and industrial cooling systems. It’s toxic to humans but used in certain applications due to its performance advantages.
  • Propylene glycol  – Often used in applications with higher safety or regulatory requirements. It’s generally recognized as safe (GRAS) by the FDA and found in food grade applications, cosmetics, and pharmaceuticals.

Understanding the Real Value of Glycol in Industrial Applications

Glycol is one of those products that hides in plain sight. It’s not flashy, not overly complex, and yet it plays a critical role in keeping the critical systems that power industrial, commercial, and institutional facilities running smoothly. Whether it’s protecting pipes in freezing environments, stabilizing temperature in process loops, or preventing microbial growth in idle systems, glycol is a valuable component in engineered water systems.

But using this material comes with responsibility. And not just in terms of a cost per gallon. Glycol changes water’s thermal properties, introduces potential regulatory and environmental concerns, and affects system design, treatment strategies, and long-term maintenance needs.

That’s why understanding the cost-benefit profile of glycol usage is so important – especially in industrial environments where scale, uptime, and long-term efficiency matter. This article breaks down where glycol shines, where it falls short, and how to make sure you’re getting its full value across your water-cooled or heat transfer systems.

Glycol is used primarily for its ability to:

  • Lower the freezing point of water
  • Raise the boiling point, extending operational range
  • Stabilize temperature in closed loop water systems
  • Inhibit bacterial growth and biofilm formation
  • Provide corrosion protection when combined with the right inhibitors

These physical properties make it a go-to fluid for environments where freeze protection, thermal stability, or long-term standby operation is required.

Insulated pipes in an industrial facility showcasing typical glycol uses in closed-loop systems.
Glycol uses in closed-loop systems include freeze protection, thermal stability, and corrosion control.

Where Glycol Shows Up in Industrial Cooling Systems

Glycol is used across a broad range of industrial applications, including:

  • HVAC systems with outdoor or remote cooling loops
  • Chilled water systems in manufacturing or mission-critical environments
  • Gas compressors and refrigeration loops
  • Ice rinks, cold storage, and process chillers
  • Any system needing freeze protection in low ambient temperatures

Because glycol changes water’s heat transfer properties, its use needs to be carefully calculated – balancing performance needs with long-term cost and efficiency tradeoffs.

The Tradeoffs: What Glycol Gives and What It Costs

Thermal Efficiency vs. Protection

One of the biggest performance considerations with glycol is its impact on thermal efficiency. While glycol is essential for freeze protection and corrosion control, it comes at a cost to system performance – particularly in how it affects water’s ability to transfer heat.

Compared to plain water, a typical glycol-water mixture:

  • Has a lower specific heat capacity, meaning it carries less heat per gallon
  • Increases fluid viscosity, which raises pumping requirements
  • Slightly reduces flow in systems not optimized for glycol
  • Can require higher system energy input to move and reject heat

These changes may seem minor, but over time they can increase energy costs – especially in systems designed for tight tolerances or high thermal loads.

That said, when properly dosed and integrated, glycol enables systems to operate year-round, even in extreme cold, without the risk of freezing or bacterial growth in stagnant lines. For facilities in cold climates or those with seasonal or standby cooling needs, glycol is non-negotiable.

Direct Costs: Product, Volume, and Maintenance

Glycol costs more than water – it’s that simple. The actual product cost can vary widely depending on:

  • Whether you’re deciding between ethylene glycol and propylene glycol
  • Required concentrations (e.g., 20% vs. 40% mixtures)
  • Whether you need food-grade or USP-grade product
  • Market volatility tied to ethylene oxide and propylene oxide production

In addition to the upfront chemical cost, glycol systems also require:

  • Corrosion inhibitors, which degrade over time and must be monitored and replaced
  • Buffering agents to manage pH stability
  • Routine fluid testing to monitor glycol concentration, pH, inhibitor levels, and degradation products
  • Longer start-up and flush times during commissioning or retrofit

Poor maintenance leads to system fouling, bacterial contamination, and reduced long-term efficiency – offsetting the benefits glycol is supposed to provide.

Environmental and Safety Considerations

From a regulatory and environmental standpoint, glycol is relatively safe – but not without scrutiny.

  • Ethylene glycol is classified as toxic and requires careful handling, secondary containment, and proper disposal procedures.
  • Propylene glycol is less hazardous and often chosen for applications with environmental sensitivity (e.g., near groundwater or food production or food additive concerns), but it still requires managed disposal and has a measurable environmental impact if released in large volumes.

Leaks, spills, or improper blowdown handling can raise flags with environmental compliance teams. For this reason, glycol use should be tied to strong monitoring practices, service documentation, and fluid management protocols.

When the Benefits Outweigh the Cost

Despite the tradeoffs, glycol remains an essential solution in many industrial cooling systems – especially those that operate outdoors, across multiple seasons, or in standby mode.

The key is ensuring:

  • Glycol is correctly specified (type and concentration)
  • Systems are designed or adjusted to accommodate its thermal and flow characteristics
  • Maintenance and fluid analysis are performed routinely
  • Lifecycle costs are compared not just to water – but to the cost of a freeze event, downtime, or system replacement

Program Execution: Getting Glycol Right From the Start

Proper Dosing Is Everything

The benefits of ethylene glycol and propylene glycol both – freeze protection, bacterial suppression, corrosion control – only show up when it’s correctly dosed. Too little glycol puts the system at risk. Too much, and you waste money, reduce thermal performance, and drive up pump energy.

Dosing is determined by:

  • Lowest expected system temperature
  • Glycol type (ethylene vs. propylene)
  • System volume and concentration goals
  • Desired freeze protection margin
  • Other chemical intermediates

For example, a 30% solution of ethylene glycol lowers freezing points and protects to about 10°F, while a 40% propylene glycol solution may only reach 5°F. Each requires different flow adjustments and inhibitor packages.

Monitoring for Performance and Degradation

Unlike water, glycol doesn’t just “sit” in the system. It ages. It reacts with heat, oxygen, and metals, and its inhibitor package depletes over time. Without regular testing, systems can run for months or years with degraded glycol – losing protection while silently corroding from the inside out.

EAI’s glycol programs include:

  • Routine fluid sampling (annually or semi-annually depending on system load)
  • Testing for:
    • Glycol concentration (to ensure proper freeze point)
    • pH stability
    • Reserve alkalinity (indicator of inhibitor health)
    • Presence of degradation products (acids, sludge)
  • Onsite and lab-based support depending on system complexity

Ethylene glycol and propylene glycol programs are not just about freeze protection – they’re about system stability. Just like boiler chemistry, tower water treatment, or membrane conditioning, glycol loops need regular attention.

Common Pitfalls – and How to Avoid Them

Even well-designed systems can underperform if glycol is mismanaged. Here are the most common issues:

Overdosing Glycol for “Extra Protection”

Leads to poor heat transfer, increased pump load, and wasted chemical.

Neglecting pH and inhibitor monitoring

Once inhibitors are depleted, glycol turns acidic – and that accelerates internal corrosion.

Using the wrong glycol grade

Industrial-grade ethylene glycol may be fine for closed-loop HVAC – but unacceptable near food, pharma, or groundwater discharge. The same type of misapplication can strike propylene glycol solutions. Misapplications can lead to liability or compliance issues.

Lack of circulation

Dead zones and stagnation lead to localized bacterial growth, fouling, and pressure issues – especially with improperly installed side-stream filters or long distribution runs.

EAI’s Approach to Glycol Program Management

At EAI, we don’t just deliver glycol – we manage it. Our programs are built to:

  • Specify the correct type and blend or ethylene glycol or propylene glycol for your application (HVAC, process cooling, outdoor utility systems)
  • Design fill and flush procedures that minimize air intrusion and protect pipework
  • Schedule annual analysis and inhibitor refresh as part of your regular service plan
  • Integrate with automation systems to monitor temperature, pressure, and glycol flow
  • Advise on secondary containment and environmental compliance for large-volume systems

Whether we’re supporting a new install, retrofitting an underperforming loop, or analyzing fluid from a 10-year-old chiller line, our focus stays the same: maximize uptime, minimize risk, and protect your equipment investment.

Making the Call: When Glycol Use Is Worth the Investment

Glycol isn’t a must for every system – but when it’s used correctly, its value is clear. For facilities in cold climates, mission-critical applications, or operations that demand year-round system integrity, glycol provides protection that plain water simply can’t offer.

However, getting the most out of glycol requires more than just a bulk fill. It requires understanding its performance tradeoffs, managing its chemical balance, and building the program into your system design and maintenance strategy from day one. Ethylene glycol is toxic and requires additional care, while propylene glycol usp is often chosen for applications with environmental sensitivity concerns.

Let’s recap what goes into a proper cost-benefit analysis for glycol use.

When Glycol Use Makes Sense

  • Freeze protection is essential  – Any cooling system exposed to subfreezing conditions, whether seasonal or year-round, benefits from glycol’s ability to lower the freezing point and protect pipes, valves, and pumps.
  • Standby or low-flow operation  – Glycol’s ability to suppress bacterial growth and biofilm makes it ideal for systems that cycle irregularly or sit idle for extended periods.
  • Corrosion protection is needed  – With the right inhibitors, glycol systems reduce internal metal corrosion, especially in closed-loop systems that can’t be easily flushed or maintained.
  • Access or maintenance downtime is limited  – Glycol helps minimize emergency freeze events, allowing facilities to maintain longer service cycles without risk.

When to Reconsider or Minimize Glycol Use

  • Year-round, climate-controlled indoor systems  – If freeze risk is minimal, the thermal penalty of glycol may outweigh the protection it offers.
  • Highly sensitive processes  – In applications where even minor changes in heat transfer efficiency impact process control, glycol should be reviewed carefully – or concentration minimized.
  • Open systems with frequent blowdown  – In tower-fed loops or systems with regular bleed-off, glycol loss becomes a recurring cost and environmental concern.

EAI works with clients to assess these tradeoffs before a system is commissioned or filled – balancing safety, cost, and performance based on real-world conditions.

The Bottom Line: Glycol Pays Off When It’s Done Right

Like any treatment chemical, glycol is only as effective as the program that supports it. A properly designed, maintained, and monitored glycol loop provides:

  • Long-term freeze and corrosion protection
  • Stable thermal performance across seasonal swings
  • Extended equipment life and fewer emergency service calls
  • Lower risk of microbial fouling in low-use or idle systems
  • Clear documentation and testing records to support compliance

Glycol is not just an additive – it’s a strategic decision.

How EAI Supports Smarter Glycol Decisions

At EAI, we approach both ethylene glycol and propylene glycol the same way we approach cooling towers, boilers, and closed-loop treatment – through system analysis, technical expertise, and tailored programs that match your facility’s needs.

We provide:

  • Site-specific glycol recommendations (ethylene glycol vs. propylene glycol, concentration levels, inhibitor selection, food additive concerns)
  • Fluid testing and analysis to verify performance and detect degradation
  • Program design for initial fill, retrofits, or decommissioning
  • On-call technical support to troubleshoot system performance or chemistry issues
  • Documentation and maintenance schedules to keep your program compliant and cost-effective

Whether you’re planning a new system, correcting an underperforming loop, or simply trying to reduce long-term costs, EAI delivers clarity, control, and results.

Have questions about glycol use in your facility?

Glycol isn’t a shortcut – it’s a solution. When used correctly, it protects systems from catastrophic freeze damage, supports system stability, and extends equipment life. But it requires planning, monitoring, and ongoing program maintenance to avoid becoming a liability.

If your facility is evaluating glycol use – or already has it in place – start with the fundamentals: Is it needed? Is it being maintained? And does the system support it as-is?

Contact us today or Explore EAI’s Glycol Cooling System Services we can help assess your system and recommend a glycol strategy that balances protection, efficiency, and cost.

Footer

EAI Water

For over 35 years, we’ve been in the field alongside our partners, engineering solutions tailored to enhance the lives of the people they touch.

  • Facebook
  • LinkedIn

Partnership & Membership Links

  • EVAPCO Authorized Partner
  • Association of Water Technologies Resources
  • Smart Release®

More Links

  • Water Treatment Services
  • Custom Treatment Equipment
  • Industries We Serve
  • Case Studies
  • About Us
  • Contact Us

Contact

  • (951) 272-8200
  • eai@eaiwater.com
  • 659 Brea Canyon Road, Suite 2
    Walnut, CA 91789

Copyright © 2025 · EAI Water · All Rights Reserved

  • Privacy Policy
  • Terms of Service
  • Contact Us